UPS (Uninterruptible Power Supply) installation and configuration

Preventing unscheduled power related downtime

By Ken Leyba

An inexpensive way to prevent unscheduled downtime or data loss due to power problems is with a UPS or Uninterruptible Power Supply. However, a UPS by itself is not enough for proper operation. Hardware, software, and configuration together make up a UPS system that will recover from unexpected power loss or power fluctuations that can damage systems and peripherals.
Introduction

When considering data loss, system downtime and disaster recovery, backup methods are primarily discussed. There are many methods of preventing data loss, including clustering, backup, security and power conditioning. Proper power can prevent an initial disaster from ever occurring. Providing proper power can be in the form of an Uninterruptible Power Supply or UPS. A UPS has rechargeable batteries to supply emergency power in the event of immediate power loss. If the power loss is longer than the batteries can supply, then the UPS can signal the server to initiate a power down sequence to properly shutdown, preventing data loss. When power is returned the server can return to operation after having made a clean shutdown.

Other power related problems that occur can be minimized with the circuitry of a UPS. Voltage sags and spikes, brown outs and line noise (from other machinery like elevators, air conditioners or office equipment), can all be isolated by a UPS. These power related fluctuations can wreak havoc on systems and devices. For a relatively low cost a UPS can prevent downtime due to power anomalies.
Network UPS Tools

The Network UPS Tools (NUT) [1] are a group of tools that are used to monitor and administer UPS hardware. NUT uses a layered scheme of equipment, drivers, server and clients. The equipment consists of the monitored UPS hardware. Drivers specific to the UPS hardware communicate or poll the UPS for status information in the form of variables. The driver programs talk directly to the UPS equipment and run on the same host as the server. The server upsd serves data from the drivers to the network. Clients talk to the upsd server and initiate tasks with the status data.

As indicated by the name, Network UPS Tools, NUT is a network based UPS system that works with multiple UPSs and systems. One of the many features of NUT allows multiple systems to monitor a single UPS, not requiring special UPS sharing hardware connections. The master/slave relationship synchronizes shut-downs so the slaves can initiate power-down sequences before the master switches off UPS power.

This article details the installation and configuration of a single system with a UPS connected to the serial port of the system. This is the natural first step of getting NUT installed and configured. If the UPS will supply more than one system, the second and subsequent systems can be configured as slaves.

The NUT developers also have a different take on when the systems should be powered down. NUT will wait until the UPS is “on battery” and “low battery” before it considers the UPS “critical”. This philosophy gets the most out of the UPS batteries and will wait until the critical moment to initiate a power down sequence, just in case the power comes back on line. There is an option to override this behavior if desired with upssched, which can be found in the documentation. With the upssched utility, commands can be invoked based on UPS events.

In typical GNU/Linux fashion, NUT is not the only tool available for monitoring a UPS. Apcupsd [2] is used for power management and control of APC model UPSs. There are also several graphical frontends for workstation class machines.
Preparing for installation

Prior to installing and using a UPS and its associated software, a few things must be in place. Since the system is going to be shutdown there must be a way to bring the system back up when power returns. The system BIOS needs to be configured correctly. Most modern BIOSes have an option to power-on when main power, now supplied by the UPS, is returned. Server system BIOSes will most likely support the “power on when power returns” option. If the BIOS does not support this option (more common with workstation class systems), a BIOS update may correct it. With servers configured headless, without a monitor or keyboard, there are also settings to ignore keyboard errors. Commonly these types of systems are administered via SSH or administration utilities like Webmin [3].

The UPS must also have the correct signal cable from the UPS to the system. With a USB type of UPS this is not a concern. A UPS that communicates via the serial port needs the correct signal cable that supports intelligent signaling between the UPS and system. See the UPS vendor for the correct cable or a custom cable can be built with information from the Network UPS Tools web site.

Read more at www.freesoftwaremagazine.com

Advertisements

Leave a Reply

Fill in your details below or click an icon to log in:

WordPress.com Logo

You are commenting using your WordPress.com account. Log Out / Change )

Twitter picture

You are commenting using your Twitter account. Log Out / Change )

Facebook photo

You are commenting using your Facebook account. Log Out / Change )

Google+ photo

You are commenting using your Google+ account. Log Out / Change )

Connecting to %s